TRIOL TM01-05
Place an orderDistinctive benefits
Investment Savings
Cost savings during commissioning and well operation
Increased production through quality and timely solutions
Increased service life of submersible equipment
Ensuring the safety of personnel at wells site
Operating temperature range
About product
Sustainable and optimal solution
Downhole Measuring System Triol TM01-05 is a sustainable and optimal solution for systems with a need to monitor pressure and temperature at a pump discharge; to collect, process, display and quickly transfer motor actual parameters, well parameters, at fluid temperature up to 150°C (302°F), fluid temperature at pump discharge up to 250°C (482°F) and equipment suspension zone pressure up to 40 MPa (5800psi).
Distinctive benefits of Downhole Measuring System Triol TM01–05:
Investment Savings, Cost savings during commissioning and well operation, Increased production through quality and timely solutions, Increased service life of submersible equipment, Ensuring the safety of personnel at wells site.
Displaying and processing of
- pump discharge pressure
- pump intake pressure
- ambient temperature
- submersible motor oil temperature or the temperature of the motor stator winding
- ambient temperature
- ESM vibration acceleration in the X, Y and Z axis
- insulation resistance in the circuit “Step-up transformer – submersible cable – ESM”
Specifications
Key parameters |
|
Ambient temperature |
|
ESM oil temperature / ESM stator winding | From 0 to +200/250 °С (from +32 to +392/482 °F) ±2°С, (±3,6°F), resolution 0,01°С (0,1°F) |
Pump intake pressure |
0-40 MPa (0-5800 psi) ±0,2 MPa (±30 psi), resolution 0,001 MPa (0,1 psi) |
Pump discharge pressure |
0-40 MPa (0-5800 psi) ±0,2 MPa (±30 psi), resolution 0,001 MPa (0,1 psi) |
Axis vibration x, y, z | 0-30 m/s² (±5 %), resolution 0,1 m/s² (0.001 g) |
Insulation resistance "Step-up transformer – ESM power line" | 0-1000 kΩ (±10 %), resolution 1 kΩ /
1000-10000 kΩ ±10 %, resolution 1 kΩ |
Operation mode (duration) | Extended |
Data update time | 30 s |
Controller communication protocol | RS-232, RS-485 Modbus RTU |
Communication protocol Step-up transformer / Submersible unit | Closed |
Exchange protocol Surface unit / VSD | Triol / Transfer |
Data transfer speed | 19200 8N1 |
Additional Options
Options | |
Digital Module TM01 | 16 digital inputs / 8 digital outputs |
Analog Module TM01 | 8 digital outputs |
Adam TM01 | Adapter RS485/422/232 Ethernet |
Triol High-Voltage Choke IP20 | 230х460х142mm, 24 kg, IP20, from -40 to +60°С (from -40 °F to +140 °F) |
Triol High-Voltage Choke IP56 | 230х460х142mm, 24 kg, IP20, from -40 to +60°С (from -40 °F to +140 °F) |
Triol Test unit TM01 | 454х324х171mm, 11 kg, IP67, from -40 to +55°С (from -40 °F to +131 °F), 4h |
Triol Test unit pressure TM01 | 454х324х171mm, 9 kg, IP67, from -20 to +60°С (from -4 °F to +140 °F) |
SCP Modem | Modem type depends on the region of implementation |